Oregon-scientific Atomic Projection Clock with Weather Forecast BAR6 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Zegar Oregon-scientific Atomic Projection Clock with Weather Forecast BAR6. Oregon Scientific Atomic Projection Clock with Weather Forecast BAR623PA User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
1
EN
Alarm ...................................................................... 11
View Alarm Settings ......................................... 11
Set Alarm .......................................................... 11
Activate Alarm .................................................. 11
Silence Alarm ................................................... 12
Weather Forecast .................................................. 12
Temperature .......................................................... 13
Select Temperature Unit ................................... 13
Minimum / Maximum Records .......................... 13
Moon Phase ........................................................... 13
Backlight ................................................................ 13
Reset System ........................................................ 14
Projection Unit ...................................................... 14
Safety and Care ..................................................... 14
Warnings ................................................................ 14
Troubleshooting .................................................... 15
Specifications ........................................................ 16
Main Unit Dimensions ...................................... 16
Remote Sensor Dimensions ............................. 16
Temperature ..................................................... 16
Remote Sensor (THN122N) ............................. 16
Clock / Projector ............................................... 16
Power ............................................................... 17
About Oregon Scientific ....................................... 17
FCC Statement ...................................................... 18
Declaration of Conformity ................................. 19
CONTENTS
Contents ................................................................ 1
Introduction ........................................................... 2
Product Overview ................................................. 2
Front View ......................................................... 2
Back View ......................................................... 3
LCD Display ...................................................... 4
Remote Sensor (THN122N) .............................. 5
Getting Started ...................................................... 6
Batteries ............................................................ 6
AC Adaptor ........................................................ 7
Adjust Settings .................................................. 7
Remote Sensor (THN122N) .................................. 8
Set Up Sensor ................................................... 8
Data Transmission ............................................ 9
Search for Sensor ............................................. 10
Clock ...................................................................... 10
Turn Atomic Clock Signal ON / OFF ................. 10
Set Time Zone / Clock / Calendar ..................... 11
Switch Clock Display ......................................... 11
Atomic Projection Clock with
Weather Forecast
Model: BAR623PA
USER MANUAL
Przeglądanie stron 0
1 2 3 4 5 6 ... 20 21

Podsumowanie treści

Strona 1 - USER MANUAL

1ENAlarm ... 11View Alarm Settings ... 11Set

Strona 2 - PRODUCT OVERVIEW

10ENTo force a manual search for atomic clock signals, pressand hold for 2 seconds. If no signal is found, checkthe batteries.TURN ATOMIC CLOCK S

Strona 3 - °C / °F switch

11ENSET TIME ZONE / CLOCK / CALENDARYou only need to do this if the unit is unable tosynchronize with the atomic clock broadcast, or if youhave disabl

Strona 4

12ENSILENCE ALARMWhen the alarm time is reached, the crescendo alarmwill sound for 2 minutes. To silence the alarm:• Press SNOOZE to silence it for 8

Strona 5

13ENMOON PHASEThe Calendar must be set for this feature to work, see“Set Clock” section.• Press or to view the moon phase for the nextor previ

Strona 6 - GETTING STARTED

14ENRESET SYSTEMThe RESET button is located in the main unit batterycompartment. Press RESET when you change thebatteries and whenever performance is

Strona 7

15EN• Never immerse the product in water. This cancause electrical shock and damage the product.• Do not subject the main unit to extreme force,shock,

Strona 8 - REMOTE SENSOR (THN122N)

16ENSPECIFICATIONSMAIN UNIT DIMENSIONSL x W x H 3.6 x 6.6 x 2.1 inches(92 x 167 x 53 mm)Weight 8.04 ounces (228 grams)without batteryREMOTE SENSOR DIM

Strona 9

17ENCalendar MM / DD; weekday in5 languages (E, D, F, I, S)Alarm Single alarm with2-minute crescendo and8-minute SnoozeProjector Outdoor temperaturean

Strona 10

18ENand on, the user is encouraged to try to correct theinterference by one or more of the following measures:• Reorient or relocate the receiving ant

Strona 11

19ENDECLARATION OF CONFORMITYThe following information is not to be used as contactfor support or sales. Please call our customer servicenumber (liste

Strona 12 - WEATHER FORECAST

2ENINTRODUCTIONThank you for selecting the Oregon Scientific™ AtomicProjection Clock with Weather Forecast (BAR623PA).This device bundles precise time

Strona 13 - BACKLIGHT

Atomic Projection Clock with Weather ForecastModel: BAR623PAUSER MANUAL

Strona 14 - WARNINGS

© 2004 Oregon Scientific. All rights reserved.P/N.: 086-003565-015

Strona 15 - TROUBLESHOOTING

3ENBACK VIEW1. Projector FOCUS knob2. Projector IMAGE ROTATION knob3. PROJECTION ON / OFF switch4. AC / DC adaptor plug cover5. Battery compartment (c

Strona 16 - SPECIFICATIONS

4ENLCD DISPLAY1. Weather display2. Atomic clock signal icon3. Alarm activated4. Alarm setting5. Time6. Indoor temperature7. Low battery icon for main

Strona 17 - ABOUT OREGON SCIENTIFIC

5ENREMOTE SENSOR (THN122N)1. Wall mount hole2. RESET hole3. CHANNEL number (1-3)4. Battery compartment(Battery compartment cover not shown)1. LED stat

Strona 18 - FCC STATEMENT

6ENUNIT LOCATIONMain Indoor Temperature AreaRemote Outdoor Temperature AreaInstalling the batteries:GETTING STARTEDBATTERIESMain unit 3 x UM-3 (AA) 1.

Strona 19

7ENAC ADAPTORThe main unit is supplied with a 4.5V AC / DC adaptor,which provides continuous clock / temperature projection.Inserting the adaptor:ADJU

Strona 20 - Weather Forecast

8ENInstalling the batteries:Using the wall mount or stand:REMOTE SENSOR (THN122N)This product is shipped with a THN122N ThermometerSensor that collect

Strona 21 - P/N.: 086-003565-015

9ENFor best results:• Insert the batteries and before you mount thesensor.• Place the sensor out of direct sunlight andmoisture.• Do not place the sen

Komentarze do niniejszej Instrukcji

Brak uwag